loading
inquinamento gassoso

Trattamento inquinanti gassosi di molteplice formazione



DIOXINS & FURANS
2,3,7,8 - TCDD 1,2,3,7,8,9 HxCDD 1,2,3,6,7,8 - HxCDF 1,2,3,7,8 - PCDD 1,2,3,4,6,7,8 - HpCDD 1,2,4,6,7,8 - HxCDF 1,2,3,4,7,8 HxCDD OCDD 1,2,3,7,8,9 - HxCDF
1,2,3,6,7,8 HxCDD 2,3,7,8 - TCDF 1,2,3,4,6,7,8 - HpCDF 1,2,3,7,8 - PCDF 2,3,4,7,8 - PCDF 1,2,3,4,7,8,9 - HpCDF 1,2,3,4,7,8 - HxCDF OCDF 2,3,4,7,8 - PCDF
SILOXANES
Trimetilsilanolo Esametildisil ossano Esametilciclotrisilossano Octametilciclotetrasilossano
Altri contaminanti
Hydrocarbons Hydrogen sulfide VOCs Aliphatic chlorinated solvents Organic aromatic solvents



Casi studio di trattamento gassoso

Recupero energetico da discarica comunale
Contaminanti Afflusso Deflusso
ORGANIC AROMATIC SOLVENTS
Benzene 28 mg/Nm3 < 2 mg/Nm3
Toluene 219 mg/Nm3 11 mg/Nm3
Etilbenzene 175 mg/Nm3 4 mg/Nm3
O-xylene 53 mg/Nm3 < 2 mg/Nm3
Isopropilbenzene 149 mg/Nm3 < 2 mg/Nm3
Stirene 117 mg/Nm3 < 2 mg/Nm3
Propilbenzene 54 mg/Nm3 6 mg/Nm3
P-xylene 23 mg/Nm3 < 2 mg/Nm3
M-xylene 18 mg/Nm3 < 2 mg/Nm3
Mesitilene 156 mg/Nm3 < 2 mg/Nm3
SILOXANES
Esametildisilossano 14 mg/Nm3 < 2 mg/Nm3
Octametiltrisilossano 8 mg/Nm3 < 2 mg/Nm3
Decametiltetrasilossano 6 mg/Nm3 < 2 mg/Nm3
Esametilciclotrisilossano 6 mg/Nm3 < 2 mg/Nm3
Octametilciclotetrasilossano 3 mg/Nm3 < 2 mg/Nm3
ALIPHATIC CHLORINATED SOLVENTS
Triclorometano 18 mg/Nm3 < 2 mg/Nm3
Diclorometano 12 mg/Nm3 < 2 mg/Nm3
Clorometano 9 mg/Nm3 < 2 mg/Nm3
Cloruro di vinile 6 mg/Nm3 < 2 mg/Nm3
1,2-Dicloroetano 21 mg/Nm3 < 2 mg/Nm3
1,1-Dicloroetilene 7 mg/Nm3 < 2 mg/Nm3
Tricloroetilene 21 mg/Nm3 < 2 mg/Nm3
Tetracloroetilene 26 mg/Nm3 < 2 mg/Nm3
CORROSIVE AND HARMFUL GASES
Hydrogen sulfide 0,0145 % voldry < 0,0001 % voldry
impianto di incenerimento dei rifiuti
Contaminanti Afflusso Deflusso
2,3,7,8 - TCDD 6,895 ng/Nm3 0,0019 ng/Nm3
1,2,3,7,8 - PCDD 39,726 ng/Nm3 0,0074 ng/Nm3
1,2,3,4,7,8 HxCDD 53,399 ng/Nm3 0,0214 ng/Nm3
1,2,3,6,7,8 HxCDD 146,988 ng/Nm3 0,0735 ng/Nm3
1,2,3,7,8,9 HxCDD 84,616 ng/Nm3 0,0202 ng/Nm3
1,2,3,4,6,7,8 - HpCDD 947,505 ng/Nm3 0,1332 ng/Nm3
OCDD 1329,817 ng/Nm3 0,2540 ng/Nm3
2,3,7,8 - TCDF 65,453 ng/Nm3 0,0328 ng/Nm3
1,2,3,7,8 - PCDF 108,139 ng/Nm3 0,0727 ng/Nm3
2,3,4,7,8 - PCDF 259,811 ng/Nm3 0,0833 ng/Nm3
1,2,3,4,7,8 - HxCDF 582,396 ng/Nm3 0,2712 ng/Nm3
1,2,3,6,7,8 - HxCDF 419,515 ng/Nm3 0,1664 ng/Nm3
1,2,4,6,7,8 - HxCDF 803,314 ng/Nm3 0,2058 ng/Nm3
1,2,3,7,8,9 - HxCDF 206,660 ng/Nm3 0,0505 ng/Nm3
1,2,3,4,6,7,8 - HpCDF 1588,510 ng/Nm3 0,6000 ng/Nm3
1,2,3,4,7,8,9 - HpCDF 613,354 ng/Nm3 0,1774 ng/Nm3
OCDF 2361,344 ng/Nm3 0,6317 ng/Nm3
2,3,4,7,8 - PCDF 259,811 ng/Nm3 0,0833 ng/Nm3
Rimozione di vapori organici in una fabbrica di resine
Contaminanti Afflusso Deflusso
Styrene 1400 mg/Nm3 < 0,1 mg/Nm3
Acetone 98 mg/Nm3 < 0,0072 mg/Nm3
© 2024 Team Service P.I IT01746590494 - REA: LI - 154345 - Via degli arrotini, 83 - 57121 Livorno - Tel. 0586 1837392 [angiolini]